To ensure operational safety and reduce the chance of other equipment being corroded by the electrolyte during titanium anode cyclone electrolysis,as well as to perform preliminary rinsing of the cathode copper,it is recommended to rinse the electrolytic cell before opening(or treating)it.In addition,during product collection,it is recommended that the electrolytic cell be in a"full"state,which can provide additional"lubrication"when removing cathode products from the electrolytic cell.Generally speaking,electrolytic cells need to be flushed in the following situations:before repairing the electrolytic cell during product collection,the cyclone electrolysis device is normally used for product collection when the power is off.Therefore,flushing water is generally used to flush the modules.
Open the flushing water valve to allow"clean"water to flow into the electrolytic cell module through the pipeline.The flushing of the electrolytic cell depends on the displacement of electrolyte by the flushing water flowing through the electrolytic device.Therefore,at the beginning of flushing,the electrolyte still exists in the module.After the electrolyte replacement is completed,the outlet of the solution pipe is connected to the flushing liquid storage tank.A better solution is to empty the electrolyte through the discharge valves at the bottom of each row of electrolytic cells,and then flush it,which can reduce the cross contamination between flushing water and electrolyte.Before starting to refill the electrolyte into the electrolytic cell,the flushing solution should be drained.The procedure for reintroducing electrolyte is the opposite of the above process.
At the same time,the following precautions should also be taken when starting and stopping the cyclone electrolysis device:
1)Start the frequency converter and solution pump,establish the flow rate through the electrolysis module,and confirm that the air in the tank has been emptied
2)According to the process parameters,check the flow rate,adjust the frequency of the frequency converter,and adjust the flow rate to the set value
3)Open the rectifier device
4)Adjust the rectifier device to the set value(rectifier device handles constant current state)